Guide · updated 24 November 2026

How to Use a Multimeter

To use a multimeter, plug the black probe into COM and the red probe into the jack for what you measure, turn the dial to the right function, and touch the probes to the circuit: across a part for voltage, across a part with the power off for resistance and continuity, and in series with the load for current. Read the value and its unit on the display. This guide explains the dial and the jacks, the safety rules, and each basic measurement step by step.

iPhone and iPad (iOS 17 or later): free on the App Store. Android later.

Gloved hands holding test probes to a row of contactors in an open control cabinet

At a glance

Measurement Dial Red probe How the probes go
DC voltage V VΩ Across the part, circuit on
AC voltage V VΩ Across, with a rated meter and probes
Resistance Ω VΩ Across, power off
Continuity VΩ Across, power off
Current A A or mA In series, circuit opened
Capacitance VΩ Across, discharged, power off
Diode VΩ Red on the anode, power off

The black probe always goes in COM.

Safety first

Safety. Use a meter and probes rated for the place you measure: the CAT rating (CAT II, III or IV) and the voltage printed next to it must cover the circuit. Check the probes before use: no cracked insulation, no bare metal above the finger guards, and keep your fingers behind the guards. Never measure current with the probes across a voltage source. Switch the power off for resistance, continuity, capacitance and diode tests. If you are not trained for mains work, do not measure mains circuits.

CAT II is for equipment plugged into an outlet, CAT III for the fixed installation of a building (distribution boards, fixed wiring), and CAT IV for the supply side (the meter and the service entrance). A higher category is built for larger voltage spikes. A meter rated CAT III 600 V is not safe on a CAT IV circuit, even at a lower voltage.

Measurement categories: CAT II for equipment plugged into an outlet, CAT III for the fixed installation, CAT IV for the supply sideCAT IVSupply side, serviceentranceCAT IIIFixed installation, boardsCAT IIEquipment on an outlet
The higher the category, the larger the voltage spikes the meter is built for.

The dial, the jacks and the display

The dial picks the function. Each position has a symbol: V with a straight line for DC voltage, V with a wavy line for AC voltage, Ω for resistance, a sound-wave symbol for continuity, a diode symbol, A for current, and often capacitance, frequency and temperature. A function button (SELECT or FUNC) switches between functions that share a position. The multimeter symbols chart explains every marking.

The jacks take the probes. Black always goes in COM. Red goes in the V/Ω jack for voltage, resistance, continuity, diode and capacitance, in the mA or µA jack for small currents, and in the A (often 10 A) jack for large currents. Current jacks are protected by a fuse.

The display shows the value, its unit (mV or V, Ω, kΩ or MΩ) and symbols for the mode. OL means the value is over the range, or, on resistance and continuity, an open path. A meter with auto-range picks the range itself; on a manual meter, pick the first range above the value you expect, and step down if the reading is small.

A multimeter: the display at the top, the dial with its function symbols, and four jacks with the black lead in COM and the red lead in VΩ0.000VAVVΩ10AmACOMVΩDisplayDial and symbolsJacksBlack: always COMRed: VΩ, mA µA or 10A
Black lead in COM, red lead in the jack for what you measure.

Measure voltage

DC voltage

  1. Put black in COM and red in V/Ω.
  2. Turn the dial to DC volts (V with a straight line).
  3. Touch black to minus (or ground) and red to plus. The probes go across the part; the circuit stays as it is.
  4. Read the value. A minus sign means the probes are the other way round; nothing is damaged.

A battery is the easiest first measurement. See how to test a battery with a multimeter for the steps and the charts that tell you what the number means, and the car battery voltage chart for a 12 V battery.

AC voltage

AC voltage is measured the same way as DC, with the dial on V with a wavy line. Polarity does not matter. Mains voltage can kill: use a meter and probes rated for the circuit, keep one hand away from the circuit where you can, and connect the black probe first and remove it last. On a disconnected wire a sensitive meter can show a few volts of "ghost voltage" picked up from nearby cables; some meters have a low-impedance mode (LoZ) that ignores it.

Measuring DC voltage: the dial on V DC, the red probe on the plus terminal of a 12 V battery and the black probe on minus; the display reads 12.6 V12.6VAVVΩ10AmACOMVΩ−+12 VAcross the partRed on +, black on −
DC voltage: the probes go across the battery, red on plus.
Measuring AC voltage at an outlet: the dial on V AC, both probes in the outlet, a meter rated CAT II or higher, one hand kept away230VAVVΩ10AmACOMVΩCAT II or higherKeep one hand awayRated probes, fingersbehind the guards
AC voltage: only with a meter and probes rated for the circuit.

Resistance and continuity

Measure resistance

  1. Switch the power off and, for a reliable value, take the part out of the circuit or lift one of its legs. Other parts in parallel change the reading.
  2. Put the probes in COM and V/Ω and turn the dial to Ω.
  3. Touch the probe tips together first. The small value you see is the resistance of the leads; subtract it from low readings, or use the REL button to zero it.
  4. Touch the probes to both ends of the part and read the value and the unit (Ω, kΩ or MΩ).

To check a resistor against its marking, read the bands with the resistor colour code chart and compare. Do not hold both probe tips and the part with your fingers: on high values, your body adds a parallel path.

Test continuity

Continuity tells you whether a path exists: the meter beeps when the resistance between the probes is below a threshold, often somewhere between 20 Ω and 50 Ω. Turn the dial to the continuity symbol, switch the circuit off, and touch the two ends of the wire, switch or fuse. A beep means connected; silence and OL mean open. The full procedure is in how to test continuity with a multimeter, and a fuse check in how to test a fuse with a multimeter.

Measuring resistance and continuity with the power off: a 4.7 kΩ resistor measured out of the circuit, and a fuse that makes the meter beepBeep: the path is closed4.70kΩAVVΩ10AmACOMVΩOut of the circuitPower off
Resistance and continuity: power off, part out of the circuit or one leg lifted.

Measure current

Current is the measurement that destroys meters and fuses, because the meter must be in series: the current flows through it.

  1. Switch the power off.
  2. Move the red probe to the current jack: the A jack if you do not know the size of the current, the mA jack only if you know it is small enough for that input's fuse.
  3. Turn the dial to A (DC or AC, as the circuit).
  4. Open the circuit at one point and connect the meter into the gap, so all of the current flows through it.
  5. Switch on and read the value. Switch off before you disconnect.

Never put the probes across a battery or a supply while the red probe is in a current jack: the meter is then almost a short circuit, and the fuse blows or worse. After a current measurement, move the red probe back to V/Ω. A clamp meter measures current around a single wire without opening the circuit. For a car battery that goes flat while parked, the parasitic draw test uses this series method.

Measuring current: the circuit is opened and the meter connected in series through the break, the red lead in the 10A jack; probes across the battery are crossed out0.35AAVVΩ10AmACOMVΩ+−In seriesOpen the circuit,meter in the gapNever across the supplyA short through the meter
Current: the meter goes in series, the red lead moves to the A or mA jack.

Capacitance and the diode test

Capacitance. Switch off, discharge the capacitor through a resistor, take it out of the circuit if you can, and turn the dial to the capacitance symbol. Large capacitors take several seconds to read. Compare the value with the marking and its tolerance. The steps and what the readings mean are in how to test a capacitor with a multimeter.

Diode test. In the diode position the meter drives a small current through the part and shows the voltage across it. A good silicon diode reads about 0.5 to 0.7 V with red on the anode and OL the other way round. A reading near 0 V both ways means a short; OL both ways means open. An LED reads higher, and may glow faintly if the meter's test voltage is high enough.

Capacitance and the diode test: a discharged capacitor reads 47.2 µF; a diode with red on the anode reads 0.62 V forward47.2 µFDischarge it first0.62 VRed on the anodeForward voltage
Capacitance on a discharged capacitor; the diode test shows the forward voltage.

Common mistakes

  • The red probe left in the current jack after a current measurement, then a voltage measurement: a short through the meter.
  • Measuring resistance with the power on. The reading is wrong, and the meter can be damaged.
  • Reading the wrong unit. 4.7 kΩ and 4.7 MΩ look alike on a small display; check the unit every time.
  • The wrong range on a manual meter: OL means the range is too low, a reading of 0.00 often means it is too high.
  • A meter with a flat battery, which can show readings that drift or are simply wrong. Replace it when the low-battery symbol shows.
  • A meter rated too low for the place you measure. Check the CAT rating before you work on an installation.

Log readings with a Bluetooth meter

With a Bluetooth multimeter, the TestNMeasure app shows the same reading on your phone. Tap the meter in the scan results to connect, and live readings start. The large readout shows which digits have settled, and an over-range shows as OL, never as a number. Swipe to a live graph of the readings. Hold freezes the reading in the app, and REL takes the lead resistance off resistance readings. One tap saves the current reading. A reading from a meter the app does not read can be typed in and is marked as manual. Export the session as CSV. Which meters the app reads is on the meters page; see also the live meter and quick capture. A test file is your record, not a certification.

Meter screen in TestNMeasure: 12.36 V DC, five stability bars lit, stats row with 5 s, 30 s and 60 s averages
The live readout: settled digits, stability bars and rolling averages.

Meters that can do this

Bluetooth multimeters from our shop that make this measurement and that TestNMeasure reads live.

Other meters the app reads live

What the app does here, and what it doesn't

What it does
What it doesPlan
Tap a result to connect; the meter becomes the active instrument and live readings start.Free
Type the reading from any instrument; typed values are marked as manual.Free
A large readout that shows which digits have settled; OL and UL are shown as OL and UL, never as a number.Free
Swipe the readout to a live graph with min and max lines, pan and zoom.Free
Hold freezes the displayed reading and statistics in the app, independent of the meter's own HOLD.Free
REL shows the difference from a stored reference, for example to null out test-lead resistance.Free
One tap saves the current reading, with an Undo.Free
Export log sessions and test files as CSV, free.Free

Not yet, or not planned

  • A test file is your record, not a certification.

Questions

How do I use a multimeter for the first time?

Put black in COM and red in V/Ω, turn the dial to DC volts and measure a battery: black on minus, red on plus. Then try resistance on a resistor with the power off, and continuity on a wire. Leave current until you have read how the series connection works.

Which setting do I use to measure voltage?

V with a straight line (often with dashes) for DC, such as batteries, car circuits and electronics. V with a wavy line for AC, such as mains outlets. Use the first range above the voltage you expect if your meter is not auto-ranging.

Why does my multimeter show OL?

OL means overload or over-range: the value is above the selected range, or, on resistance and continuity, the path is open. Pick a higher range, or check that the probes touch clean metal and the path is complete.

Can I measure current like voltage, across the part?

No. Current is measured in series, with the circuit opened and the meter in the gap. With the probes across a voltage source in a current jack, the meter is a short circuit and the fuse blows.

Try it in the demo

A simulation of the app in your browser, with made-up readings: no meter and no install needed.

Get TestNMeasure for iPhone and iPad.

iPhone and iPad (iOS 17 or later): free on the App Store. Android later.

Questions or a meter to suggest? Mail support@testnmeasure.app.

No ad networks, no sign-up.